PCR Workstation

workstation,dead air,pcr workstation,kiagen,cabin uv,uv workstation

kiagen

11/24/2020 7:44:26 PM | 19:44 0 comments 2082 visits

Kiacab PCR Workstation

Dead Air Box

Polycarbonate and polypropylene design to reflect UV energy

Safety switch to prevent exposure to harmful UV energy

Full access folding sash

minute manual UV light timer

Unibody plastic design - no joints or gaps in construction

Dimentions: 50*68*70cm D*H*W

UV and fluorescent lights

KIACab PCR Workstation

KIACab PCR Workstation brings UV radiation to create an environment against PCR contamination. Choose from cabinet or workstation. The cabinet features a smaller work area than the workstation.

Main Feature :

Control potential PCR contamination with the built-in KIACab PCR for inactivation of DNA between experiments.

The 254nm shortwave UV source positioned as overhead UV; select models include KIACab PCR air recirculator to circulate the sterilized air.

UV is controlled with a key switch and 30-minute timer to decontaminate apparatus and chamber with the shortwave UV.

The shortwave ultraviolet irradiation can be used as a standard laboratory practice to reduce surface and airborne contaminants in the chamber.

A safety shut-off switch automatically turns the ultraviolet light off when the door is open.

Antimicrobial coated stainless steel reduces bacterial growth.

The workstation is designed for placement of large instruments on the work area or tubes, flasks and pipettes on the two removable shelves.

The built-in power outlets allow operation of equipment for use in PCR applications.

KIACab PCR Workstation ionic

Multi-featured equipment for eliminating PCR contamination! HEPA/KIACab PCR models feature an air-clean system plus UV to eliminate contamination.

Main Features:

Air circulates from the KIACab ionic system into the PCR chamber via an air clean system with high/low settings. Control potential PCR contamination with built-in KIACab for inactivation of DNA

Multi-featured equipment for eliminating PCR contamination! HEPA/KIACab PCR models feature an air-clean system plus UV to eliminate contamination.

Main Features:

Air circulates from the KIACab ionic system into the PCR chamber via an air clean system with high/low settings. Control potential PCR contamination with built-in KIACab for inactivation of DNA between experiments. Shortwave UV can be used as a standard laboratory practice to reduce surface and airborne contaminants in the chamber.

4 Stage Purification System:

  • Activated carbon filter.
  • UV light
  • Photo-catalyst filters
  • Negative ion generator


Leave a comment